Zelenograd, Savelkinsky proezd, 4, 6th floor
Modular measuring instruments and ATE systems
Contact form
    RUS

FKU30x6 AXIe-0

FKU30x6 AXIe-0
Order
Item article: FKU30x6 AXIe-0 module
Order
The new FKU30x6 AXIe-0 module 30x6 matrix switcher (30 input channels - 6 output lines) is specially designed for cable test systems series TEST-9110 for the tasks of testing the relay boxes.
The module can function as part of the automated measuring systems of the TEST-9110 series and is integrated into the AFK9110 software and allows you to significantly expand the capabilities of the TEST-9110.

The module is made in the AXIe-0 standard.


The FKU30x6 AXIe-0 module implements the structure of a 30x6 matrix switcher (30 input channels - 6 output lines). The module is designed to work in functional control systems, quality control systems for Functional Testing / Diagnosis of various Relay boxes, control systems and diagnostics of electronic equipment, control systems for bench tests.


The module performs the function of switching 30 input channels on 4 command and 2 measuring output lines.


The module provides monitoring of the switch state at the level of the relay control register (closed / open).


The module provides registration of the number of operations of each relay with saving the results in non-volatile memory.


The module provides the ability to open the contacts of all relays by one command from the PC.


The module provides verification of the main technical characteristics in the "Self-control" mode.

Switching voltage (command lines):

1 mV to 32 V DC

1 mV to 250 VAC

Switching current (command lines):

1 mA to 10 A constant

1 mA to 10 A AC

Maximum switching power (command lines):

300 watts 1200 VA

 

Switching voltage (measuring lines):

1 mV to 1000 V DC / AC

Switching current (measuring lines): 1 mA to 0.5 A

Pass-through current (measuring lines): 1 mA to 1 A

Time of closing / opening of relay contacts, no more: 10 ms;

Initial resistance of any switching circuit with closed relay contacts: 0.6 Ohm

Electrical strength of galvanic isolation between any input and output lines, between any input line and the case, as well as between any output line and the case, not less than 1000 V

Galvanic isolation resistance between any pair of input lines, between any pair of output lines, between any input and output lines, between any input line and the case, as well as between any output line and the case, not less than 100 MΩ

 Dimensions (L x W x H) 280 x 30.48 x 322.75 mm     Weight 3.4 kg
FKU30x6 AXIe-0