DESTINATION AND USAGE FIELD

Automated measuring system TEST-2402-01-AIK is intended for measurement, generation and control of electrical values. System is used during realization electrical tests of control objects (CO).

Main system's functions:
  • Reproduction direct current power or direct current voltage of given value by galvanic free from each other and from module case channels;
  • Generation of 30 impulse commands by closing of relay contact (“dry contact”);
  • Measuring of direct current voltage, direct current power of direct current resistance;
  • Setting on mezzanine carrier up to four mezzanines and realization their functions;
  • Measuring of direct current voltage to 32 two-wire isolated each from other channels;
  • Measuring of value active resistance to two-wire scheme to 96 independent channel, isolated from control scheme and case;
  • Measuring of value active resistance to four-wire scheme to 64 independent channels, isolated from control scheme and case;
  • Analysis of 256 discrete signals with definition of next condition type of discrete sensors.
  • Unpowered relay contact ;
  • Unpowered electronic key;
  • Powered electrical key;
  • Generation of 192 impulse commands be closing of relay contact (“dry contact”);
  • Controlled in time 8 group switch, in each of which any from two inputs lines switched on any from 30 outputs lines;
  • Measuring of voltage instantaneous value in range up to 50 V to 64 differentials isolated each from other channels;
  • Receiving and transformation telemetric information’s, incoming like frame as cyclic periodic consecution impulse signals in type of BITS-2T structure;
  • Data communication via RS-22 interface to four channels;
  • Data communication via interface under MIL Std 1553B to 3 channels;
  • Generation of supply voltage direct current in range from 0 to 27 V with load current up 10 A;
Self-check mode realize the following functions:
  • Reproduction direct current power or direct current voltage of given value by galvanic free from each other and from module case channels;
  • Software value settings of resistance in 3 independent channels;
  • Digital signals oscillography with frequency digitization (sample) 100 MHz by two independent channels;
  • Analog signals switching from 50 input lines to eight outputs lines;
  • Analog signals switching by six groups, each group with 100 inputs lines on four outputs lines;
  • Measuring of direct current voltage, direct current power of direct current resistance;
  • Generation of supply voltage direct current to three channels in range from 0 to 35 V with load current up to 3 A and to one channel in range from 0 to 100V with load current up to 1 A.